PMFT 1000
- Description
- MEASUREMENT APPLICATION
- TECHNICAL PARAMETER
- VIDEO
- DOWNLOAD
Description
Test of respiratory masks better than the standard. Exact analysis of filter mask efficiency from 145 nm up to 40 µm.
SARS-CoV-2 size approx. 120 nm – 160 nm.
• Test rig working principle better than EN 143, EN 149 and EN 13274-7
• Forfills requirements in accordance with GB 2626 (with CD 2000)
• Testing of fractional efficiency, e.g. efficiency in whole size range of 145 nm up to 40 µm
• Exact analysis of filter and filter mask efficiency for Corona Virus (size approx. 120 nm up to 160 nm) starting at 145 nm
• Future proof: Works with any kind of aerosol without adjustments
• Further measurement of differential pressure, e.g. as well within different face velocities
• Face velocity adjustable between 1.5 – 50 cm/s
• Product capable of fast quality assurance AND continuous optimization in R&D (display of size distribution)
• Individual face mask adapter for your product
• Attractive 2 years maintenance package for availability of test rig
Description
Test of respiratory masks better than the standard with additionally exact analysis of filter mask efficiency for SARS-CoV-2 (size approx. 120 nm up to 160 nm). Display of efficiency from 145 nm.
• Test rig working principle better than EN 143, EN 149 and EN 13274-7
• Equivalent to GB 2626 and 42 CFR 84 by additional software option
• Fullfills additionally the requirements according to GB 2626 (Filter efficiency, CD 2000 discharge unit is required)
• Testing of fractional efficiency, e.g. efficiency in whole size range of 145 nm up to 40 µm
• Exact analysis of filter and filter mask efficiency for SARS-CoV-2 (size approx. 120 nm up to 160 nm). Efficiency also displayed at 145 nm
• Future proof: Works with any kind of aerosol without adjustments
• Further measurement of differential pressure, e.g. as well within different face velocities
• Face velocity adjustable between 1.5 – 50 cm/s
• Product capable of fast quality assurance AND continuous optimization in R&D (display of size distribution)
• Individual face mask adapter for your product
• Attractive 2 years maintenance package for availability of test rig
• Can be operated as Mas Q-Check with optional Mas-Q-Head
PMFT 1000 M is based on Palas® MFP 1000.
Pictured: Analysis of filter and filter mask efficiency for Corona Virus
The size distribution of the test aerosol according to the standard is as follows:
Oil: Geom. standard deviation 1,8 | Median diameter 301 nm
Pictured: DEHS size distribution
NaCl: Geom. standard deviation 2,1 | Median diameter 63nm
Pictured: NaCl size distribution
Overview of standards for face mask penetration testing
EN 149 | EN 13274-7 | EN 13274-7 | GB 2626 | GB 2626 | 42 CFR 84 | 42 CFR 84 | |
Aerosol | see EN 13274-7 | NaCl | PaO | NaCl | PaO/DOP | NaCl | DOP |
Mean diameter | see EN 13274-7 | 0.06 – 0.1 µm | 0.29 – 0.45 µm | 0.055 – 0.095 µm | 0.165 – 0.205 µm | 0.055 – 0.095 µm | 0.165 – 0.205 µm |
Standard deviation | see EN 13274-7 | 2 – 3 | 1.6 – 2.2 | < 1.86 (by additional software module) | < 1.6 (by additional software module) | < 1.86 (by additional software module) | < 1.6 (by additional software module) |
Concentration | see EN 13274-7 | 4 –12 mg/m³ | 15 – 25 mg/m³ | < 200 mg/m³ | (50 mg/m³) < 200 mg/m³ | < 200 mg/m³ | < 200 mg/m³ |
Discharge | – | – | – | required | required | required | required |
Air flow | see EN 13274-7 | 95 l/min | 95 l/min | 85 ± 4 l/min | 85 ± 4 l/min | 85 ± 4 l/min | 85 ± 4.25 l/min |
Temperature | see EN 13274-7 | 22 ± 3 °C | – | 25 ± 5 °C | 25 ± 5 °C | 25 ± 5 °C | 25 ± 5 °C |
Rel. humidity | see EN 13274-7 | < 40 % | – | 20 – 40 % | – | 20 – 40 % | 20 – 40 % |
(by compressed air) | (by compressed air) | (by compressed air) | |||||
Measurement device | see EN 13274-7 | Sodium flame photometer | Light scattering photometer | particle detector | particle detector | Light scattering photometer | Light scattering photometer |
Measuring time | see EN 13274-7 | 30 s | 30 s | lowest eff. during loading | lowest eff. during loading | lowest eff. during loading | lowest eff. during loading |
Pause time | see EN 13274-7 | 180 s | 180 s | lowest eff. during loading | lowest eff. during loading | lowest eff. during loading | lowest eff. during loading |
Exposition | 120 mg | 120 mg | 120 mg | 200 ± 5 mg | 200 ± 5 mg | 200 ± 5 mg | 200 ± 5 mg |
PMFT remarks | O.K. | O.K. | O.K. | O.K. with upgrade KIT | O.K. with upgrade KIT | O.K. with upgrade KIT | O.K. with upgrade KIT |
Benefits
• Test rig working principle better than EN 143, EN 149 and EN 13274-7
• Forfills requirements in accordance with GB 2626 (with CD 2000)
• Testing of fractional efficiency, e.g. efficiency in whole size range of 145 nm up to 40 µm
• Exact analysis of filter and filter mask efficiency for Corona Virus (size approx. 120 nm up to 160 nm) starting at 145 nm
• Future proof: Works with any kind of aerosol without adjustments
• Further measurement of differential pressure, e.g. as well within different face velocities
• Face velocity adjustable between 1.5 – 50 cm/s
• Product capable of fast quality assurance AND continuous optimization in R&D (display of size distribution)
• Individual face mask adapter for your product
• Attractive 2 years maintenance package for availability of test rig
Applications
• Test of respiratory masks
• Exact analysis of filter mask efficiency for e.g. Corona Virus
• Filter testing for HEPA quality
• Can be operated as Mas-Q-Check with optional Mas-Q-Head
Measurement range (size) | 0,10 – 40 µm |
Volume flow | 1 – 27 m3/h (Druckbetrieb) |
Power supply | 115/230 V, 50/60 Hz |
Dimensions | approx. 600 • 1,800 • 900 mm (W • H • D) |
Installation conditions | 19 –23 °C |
Inflow velocity | 5 – 100 cm/s (others on request) |
Differential pressure measurement | 0 – 1200 Pa |
Test area of the medium | 100 cm² |
Aerosols | Dusts (e. g. SAE dusts), salts (e. g. NaCl, KCl), liquid aerosols (e. g. DEHS) |
Aerosol concentrations | For SAE Fine without additional dilution up to 1,000 mg/m3 (ISO A2 Fine) |
Compressed air supply | 6 – 8 bar |